Search results for "Arsenazo III"
showing 4 items of 4 documents
Systematic Study of Several Causes and Effects Due to Absorbent Blanks in Determinations of One Analyte
1999
A systematic study is performed about several factors involved in the measurements when a absorbent blank is used, as molar absorption coefficient of the formed complex, absorbance of the blank at the measured wavelength, and kind of spectrophotometer used (conventional double-beam or diode-array). It is proved that the usual methodology, measuring against reagent blank, produces less accurate measurements than those obtained against solvent blank. On the other hand, use of the H-Point standard additions method provides always equal or better results than the best ones obtained at single wavelengths by using measurements against solvent bank, at the maximum of the formed complex. To test th…
Evaluation and elimination of the blank bias error using the H-point standard additions method (HPSAM) in the simultaneous spectrophotometric determi…
1997
Abstract The aim of this report is to demonstrate the usefulness of the HPSAM in all instances where the determination of two analytes requires the use of an absorbent reagent, particularly when it does not present a constant analytical signal because of its consumption. This problem can be treated as a ternary mixture by the HPSAM method and then, the fundamentals of the method for resolving these kind of mixtures can be applied. The method can calculate the concentration of one species from spectral data at two wavelengths where the two other species present the same absorbance relationship. These wavelength pairs are easily found, and can be selected to give the most precise results. The…
A chemometric study of the simultaneous determination of calcium and magnesium in natural waters
1999
A method for the simultaneous spectrophotometric determination of calcium and magnesium in mineral waters with an FIA system is tested. The method is based on the reaction between the analytes and arsenazo(III) at pH 8.5. The calculations of the amounts of both analytes in the samples are carried out with the H-point standard addition method (HPSAM) for ternary mixtures, and with a partial least squares (PLS) model after a proper variable selection. The results obtained for the determination of calcium were comparable using both methods. The employment of the HPSAM brings to our attention the influence of the calcium concentration in the sample to the development of the reaction between mag…
The H-point and generalized H-point standard additions methods for flow injection procedures.
1997
This paper establishes the fundamentals of the H-point standard additions method (HPSAM) and generalized H-point standard additions method (GHPSAM) in the flow injection technique. Two kinds of analytical signals can be employed, FIA peaks and spectra. Different analytical problems have been studied: determinations of one analyte in the presence or absence of matrix effect when different blank features are present, and determination of two analytes in the presence of blank bias error affecting the development of one of them. The determination of chloride with mercury thiocyanate which presents a matrix effect, and the determinations of calcium and/or magnesium with arsenazo III are examined…